A signal generator module RFQ defines the physical RF outputs, required waveforms, control interfaces, and acceptance tests for an OEM design. Two modules with similar frequency and bandwidth figures can need different wiring and software. Start with the configuration being purchased, then specify the operating conditions and evidence for each requirement.
1. What Must a Signal Generator Module RFQ Define Before Model Selection?

Name the purchased item: an SDR RF signal-source/transmit module for integration into an OEM product. State the intended application, country or region, and test environment. Then define whether the quote covers one module, several modules, or a configured assembly.
For example, an OEM might request one signal-source module with one external RF output. The buyer will provide the enclosure, DC supply, filters, and any downstream power amplifier (PA). The supplier must state whether the quote includes a mating power connector, control cable, software package, and interface documents.
A bare board and an integration-ready kit need different quotation lines. List the hardware revision, firmware version, included accessories, software deliverables, and the documents needed to bring up the module.
Give the intended quantity and stage: engineering samples, a pilot build, or a production order. The supplier can then identify which configuration the price and proposed evidence cover. Assign system-level PA, antenna, and enclosure performance to the responsible party in the RFQ.
2. How Should Frequency Range and Bandwidth Be Specified?

Write the required tuning range and the actual operating frequencies as separate fields. A module that tunes from 100 to 6000 MHz can select frequencies within that range. The range does not describe how much spectrum the module produces at one time.
The RFQ should distinguish three bandwidth terms:
- Tuning range: the frequencies the signal source can select.
- Instantaneous bandwidth: the signal span a channel can generate at one time, under the stated operating mode.
- Occupied bandwidth: the span measured for a specific transmitted waveform, using an agreed measurement method.
Tie every bandwidth request to a waveform, a center frequency, and a physical RF output. If two outputs must operate together, state the required bandwidth at each port and the simultaneous operating condition. An aggregate 200 MHz specification could describe two 100 MHz paths rather than one 200 MHz path.
List the required center frequencies, including points near the band edges. At each point, define the waveform span that must remain usable. A valid center-frequency setting alone does not establish that the required bandwidth is available near an edge. State the frequency tolerance, measurement method, and whether retuning between points is acceptable. The supplier can then quote and test each specified RF state.
For buyer-supplied waveforms, specify the IQ data format and playback settings, including sample rate, channel mapping, and loading procedure. Tie the file revision to the required RF center frequency and bandwidth.
3. Which RF Output Specifications and Connectors Must Be Listed?

Count the RF connectors that the OEM can actually use. An internal processing channel or PHY is not automatically an external RF port. For each physical output, request the connector type and gender, mating connector, nominal impedance, port label, and expected operating modes.
Define RF level at a clear reference plane, normally the module’s physical SMA output connector. Specify whether the requested figure is CW power, average modulated power, or another defined measurement. Include the test frequency, waveform, bandwidth, gain setting, load, and measurement correction. Ask for the usable output-level adjustment range under those same conditions.
A typical CW level and an OFDM level measured with a 20 MHz waveform come from different test states. Compare output power only after suppliers report the specified waveform, frequency, bandwidth, gain, load, and reference plane.
If the module drives a separate PA, define the required level at the PA input connector after source-path loss. The SDR drive-margin check uses that level and the PA’s permitted input window. Accept the source module at its own SMA output.
4. What Control Interfaces, Commands, and Firmware Details Must the Supplier Provide?

“RS422 supported” identifies an electrical interface family. It does not tell the OEM how to control a specific signal-source module. Ask for the physical connector drawing, pin assignment, signal direction, grounding guidance, serial settings, and the version of the command protocol supplied with the quoted unit.
The interface-control document should define each required command, its parameters, units, allowed values, response format, errors, and timing expectations. The OEM needs a way to set frequency, select the intended output state, query status, and recognize failed operations. Include the commands for saving settings, restarting, and reading hardware or firmware identification where supported.
Define the required RF state after power-up, restart, or loss of host communication. Request the delivered firmware’s mute/enable behavior, any automatic setting restoration, and the response to a command timeout. These details determine whether the OEM controller can recover the intended output state.
Keep three records distinct: the host sent a command, the module acknowledged it, and the RF output reached the requested physical state. Acceptance testing should examine all three when the action changes RF behavior.
The HZS1006000-F1 manual describes an RS422 interface through a five-pin GH-series connector and provides AT-command information. It also documents a USB-based custom-IQ file workflow. The file-extension labels differ within that manual, so the RFQ should request the exact format and update procedure for the offered firmware revision.
The HZSDR1006000-A01 documentation shows RS422 host control. For its dual RF outputs, request the command-to-port map and the reported state of each port after restart. For multi-module control, confirm addressing rules, supported module count, and host-software build for the quoted configuration.
5. How Should DC Power, Thermal Limits, and Mechanical Interfaces Be Written?

Specify the required DC range at the module input, connector polarity, and mating part. Request current at the buyer’s supply voltage during startup, idle, and active RF. For a dual-output module, include the state with both ports active. Each current figure should identify its voltage and RF operating condition, supported by the connector pinout and mating cable specification for the quoted hardware revision.
For thermal requirements, separate ambient temperature from the module’s mounting or heat-transfer surface. State the expected airflow, heat-sink contact, duty or operating duration, and any enclosure constraints. Ask the supplier which conditions support its operating-temperature rating and which hot-state RF measurements belong in the acceptance plan.
Mechanical data should include a revision-controlled outline drawing. Request full dimensions, mass, mounting-hole locations, connector orientation, mating parts, and cable clearance. Width and length alone leave the OEM fit check open when thickness or mounting details are missing.
6. How Do HZS1006000-F1 and HZSDR1006000-A01 Change the RFQ?

RF SKYPOWER’s SDR signal source modules include HZS1006000-F1 and HZSDR1006000-A01. Their RF-port layouts and published power test conditions differ. The A01 specification table is provisional, so the supplier must identify the offered hardware and firmware revision.
Check the published specifications in the F1 instruction manual and A01 instruction manual against the supplier’s quoted configuration.
| Parameter | HZS1006000-F1Instruction manual ↗ | HZSDR1006000-A01Instruction manual ↗ | Comparison Status / RFQ Confirmation |
|---|---|---|---|
| Product role | SDR RF signal-source/transmit module | SDR RF signal-source/transmit module | Comparable category; quote the exact hardware, firmware, and included software. |
| Tuning range | 100–6000 MHz | 100–6000 MHz | Published ranges align. Supplier must answer against the buyer’s frequency points, edges, and tolerance. |
| Instantaneous bandwidth | Up to 200 MHz | Up to 100 MHz per channel; up to 200 MHz in aggregate | Single-port and aggregate figures differ; confirm A01 bandwidth with both outputs active. |
| External RF outputs | One external SMA female RF OUT; internal Dual-PHY architecture | Two independent SMA RF outputs | Port count differs. Provide labeled connector drawings and F1 PHY-to-output mapping. |
| Published RF level | More than 5 dBm, typical CW; varies with test frequency | More than 0 dBm, 20 MHz OFDM; frequency-dependent | Different waveform test states; compare supplier results only under the RF-PWR conditions in the RFQ. |
| Host control | RS422, five-pin GH-series connector, documented AT commands | RS422 host control | Supply revision-matched pinout, serial settings, command/API reference, and software package. |
| Custom IQ workflow | USB-based update described; file-extension labels need revision matching | Custom-IQ delivery details to be confirmed | Identify supported file representation, sample rate, loading method, and software revision. |
| Multiple modules | Manual describes control of up to ten cascaded units | Host software refers to module IDs | Provide the supported count, addressing method, and restart behavior for the quoted configuration. |
| DC input | 28–32 V; 0.27 A maximum working current listed; XT30 male input | 9–32 V; 0.5 A maximum at 9 V listed | Input ranges and current test voltages differ; confirm the mating power cable and active-output state for each offer. |
| Operating temperature | 0 to +50 °C | −40 to +70 °C | Published operating ranges differ; confirm the temperature reference point and cooling arrangement. |
| Mechanical | 105 × 50 mm, 120 g; thickness to be confirmed | 140 × 60 × 14 mm; under 200 g | F1 thickness needs confirmation; check both modules’ connector clearance against the OEM mounting drawing. |
Swipe horizontally to compare both module configurations →
Choose the module by the number of physical RF paths the OEM needs, then confirm the IQ-loading route, port control, and evidence scope for the selected revision.
7. What Acceptance Tests and Evidence Should Be Included in the RFQ?

Set the module acceptance scope before suppliers quote the tests. Assign Test IDs to RF states (RF-*), control checks (CTL-*), DC checks (DC-*), thermal checks (THM-*), and traceability checks (TRC-*). Each Test ID needs its Requirement ID, operating state, expected result, and acceptance limit.
For RF tests, name the physical port, center frequency, waveform, bandwidth, gain, output mode, and measurement reference plane. Specify a conducted load or approved shielded setup, instrument settings, calibration records, and an uncertainty rule where required. The report should follow Requirement ID → Test ID → recorded result → acceptance decision. The supplier can then price representative, sampled, or per-unit test evidence.
| Verification Item | Agreed Test State and Reference Plane | Recorded Result | Supplier Evidence / Acceptance Criterion |
|---|---|---|---|
| Frequency points and band edges | RF-FREQ-* Test IDs for each center frequency and edge condition; measure at the named external RF OUT. | Set frequency, measured frequency, error, configuration, Test ID. | Point-specific limit and frequency record linked to the Requirement ID and Test ID. |
| Waveform and bandwidth | RF-BW-* Test IDs; name the port, waveform, center frequency, required usable instantaneous span, output level, spectral-quality limit, and occupied-bandwidth method. | Required and demonstrated instantaneous span with its test settings; separately, configured span, measured waveform occupied bandwidth, output level, and spectrum trace. | Agreed usable-span, output-level, occupied-bandwidth, and spectrum-quality criteria. An occupied-bandwidth trace alone does not verify the required instantaneous generation capability. |
| RF-port level and spectrum | RF-PWR-* Test IDs at the named SMA into the defined load; state power metric, gain, instrument settings, cable loss, and correction. | Raw reading, loss correction, corrected port power, spectral and spurious readings, instrument/calibration ID. | Port-specific power and spectral limits, corrected result, and trace keyed to the Test ID. |
| Independent and simultaneous outputs | RF-PORT-* Test IDs: F1 at its one external port; A01 at RF OUT 1, RF OUT 2, and both active. | Per-port level and bandwidth for each mode, tied to its Test ID. | Agreed single-/dual-output limits and paired traces for concurrent operation. |
| Control, errors, and restart | CTL-* Test IDs; quote connector, protocol, hardware/firmware, host version, commands, error cases, and restart states. | Command, acknowledgment, status, error response, restored settings, observed RF state, Test ID. | Versioned command log, observed functional result, and agreed timing or state limits per Test ID. |
| DC input and thermal behavior | DC-* and THM-* Test IDs; measure Vdc/Idc at module input; define startup, RF load, cooling, ambient, and stabilized thermal states. | Voltage/current, temperature, duration, RF readings, operating state, and Test IDs. | Agreed DC, current, and hot-state RF limits; test duration and cooling record linked to each Test ID. |
| Unit and report traceability | TRC-* check IDs; identify hardware, firmware, configuration, physical ports, and sample or delivery scope. | Unit ID or S/N, revisions, test date, report reference, coverage, and check ID. | Agreed report fields and verification of per-unit, sampled, or representative coverage. |
Swipe horizontally to review all acceptance-evidence fields →
A module-level acceptance clause can read: “For each approved Test ID, record the linked Requirement ID, hardware and firmware revision, test state, observed result, supporting trace or log, and decision against the agreed limit. For RF power tests, include the raw reading, path correction, corrected connector power, calibration reference, and uncertainty decision rule. Mark any test without an agreed limit as open.”
When the OEM assembly includes a PA, give PA input-power verification separate system-level Test IDs. Keep those measurements outside the source-module acceptance report.
8. How Should the Final RFQ and Supplier Response Matrix Be Organized?

Send every supplier the same revision-controlled RFQ. Replace the matrix prompts with buyer values, units, limits, and operating conditions. Mark each independently judged requirement M (mandatory) or P (preferred), and map each testable Requirement ID to the approved Test IDs. Remove rows outside the purchased configuration. If a row stays for comparison, the buyer may approve N/A with a reason. For example, a single-output RFQ can exclude the simultaneous dual-output test in BW-03.
The supplier fills the offered values for its quoted hardware and firmware revision. In the last column, S is the supplier’s declaration: C (complies), D (deviation), or O (open). B is the buyer’s quotation-stage decision: Accepted, Pending, Rejected, or buyer-approved N/A. For an N/A row, leave S blank and record the reason. An accepted deviation needs a deviation ID, the approved alternative limit or condition, a named buyer approver, and a decision date.
For existing evidence, cite the document ID, revision, and page. For post-award tests, state the test-plan or report-template revision and delivery milestone. Actual unit IDs and report results follow testing; quote acceptance and delivered-unit test PASS are separate decisions.
| RFQ Item | Buyer Requirement | Supplier Response | Evidence / Deliverable | Deviation / Confirmation Status |
|---|---|---|---|---|
| Completion key | Buyer: [M/P; required value, unit, and condition]. | Supplier: [offered value and quoted revision]. | [Existing document ID/rev/page or planned report/template ID and due stage]. | [S: C/D/O; B: Accepted/Pending/Rejected or approved N/A; decision reason and owner; deviation ID, approved alternative, buyer approver, and date when applicable]. |
| Model and revisionCFG-01 | [M/P; application, required HW/FW baseline, sample or production stage] | [Part number; HW revision; firmware build; control-software version] | [Datasheet ID/rev/section; configuration-list ID] | [S: ___; B: ___; revision differences] |
| FrequencyFREQ-01 | [M/P; tuning range in MHz; permitted exclusions] | [Offered range and exclusions] | [Specification ID/rev/section] | [S: ___; B: ___; band exceptions] |
| FrequencyFREQ-02 | [M/P; center/edge points, tolerance, RF-FREQ Test IDs] | [Per-point commitment and conditions] | [Frequency test-plan or record ID/rev; Test IDs] | [S: ___; B: ___; point exceptions] |
| WaveformWAV-01 | [M/P; waveform family, IQ format, sample rate, file delivery] | [Supported formats, waveforms, loading procedure and revision] | [Waveform/file specification ID/rev/section] | [S: ___; B: ___; format exceptions] |
| BandwidthBW-01 | [M/P; per-port center frequency, waveform, usable instantaneous generation span, output level and power metric, spectral-quality pass limits, and operating mode; RF-BW Test IDs] | [Demonstrable span, output level, spectral quality and test conditions by port] | [Instantaneous-span and spectral-quality test-plan or report ID/rev; Test IDs] | [S: ___; B: ___; span/quality differences] |
| BandwidthBW-02 | [M/P; occupied-bandwidth limit and measurement method for each specified waveform; RF-BW Test IDs] | [Waveform-specific occupied-bandwidth results or commitments] | [Spectrum test-plan or record ID/rev; Test IDs] | [S: ___; B: ___; waveform bandwidth differences] |
| BandwidthBW-03 | [M/P or buyer-approved N/A; each port’s bandwidth with both RF outputs active; RF-PORT Test IDs] | [Supported concurrent mode and per-port bandwidth] | [Dual-output test-plan or record ID/rev; Test IDs] | [S: ___; B: ___; concurrent-mode differences or N/A reason] |
| Physical RF outputsPORT-01 | [M/P; external RF OUT count, labels, channel-to-port map] | [Physical port count, names, PHY/channel routing] | [Port-map drawing ID/rev/section] | [S: ___; B: ___; mapping differences] |
| Physical RF outputsPORT-02 | [M/P; connector type/gender and mating part for each port] | [Offered connectors and mating references] | [Connector drawing ID/rev; part reference] | [S: ___; B: ___; connector differences] |
| Physical RF outputsPORT-03 | [M/P; nominal RF impedance and connector reference plane by port] | [Impedance and named measurement plane] | [RF interface specification ID/rev/section] | [S: ___; B: ___; reference-plane differences] |
| RF output levelLEVEL-01 | [M/P; per-port power requirement as a minimum, maximum, or target with tolerance (dBm); CW or modulated-average metric, waveform, frequency, bandwidth, gain, load, RF-PWR Test IDs] | [Guaranteed per-port limit or target tolerance by Test ID; typical data identified separately] | [Corrected-power record or planned report template ID/rev; Test IDs] | [S: ___; B: ___; power/test-state differences] |
| RF output levelLEVEL-02 | [M/P; usable output-level range and adjustment step] | [Gain range, resolution and conditions] | [Control/specification ID/rev/section] | [S: ___; B: ___; adjustment differences] |
| Control and softwareCTRL-01 | [M/P; RS422 physical connector, pinout, signal direction and grounding] | [Connector and electrical pin assignment] | [Interface drawing ID/rev/section] | [S: ___; B: ___; wiring differences] |
| Control and softwareCTRL-02 | [M/P; serial speed, framing and host communication settings] | [Offered serial profile and settings] | [Interface-control document ID/rev/section] | [S: ___; B: ___; serial differences] |
| Control and softwareCTRL-03 | [M/P; commands/API, units, acknowledgments, errors, timing; CTL Test IDs] | [Command/response set and limits] | [Command reference ID/rev; test-plan/log IDs] | [S: ___; B: ___; command differences] |
| Control and softwareCTRL-04 | [M/P; RF state on power-up, restart, host loss and timeouts; CTL Test IDs] | [Firmware state and recovery behavior] | [Behavior specification ID/rev; test-plan/log IDs] | [S: ___; B: ___; recovery differences] |
| Control and softwareCTRL-05 | [M/P; firmware updates, IQ loading, software version and delivered files] | [Update/loading method; versioned file manifest] | [Release notes ID/rev; procedure/manifest IDs] | [S: ___; B: ___; delivery differences] |
| DC and mechanicalDC-01 | [M/P; DC voltage at module input; connector, polarity, mating cable] | [Voltage range and power-interface details] | [Power-interface drawing ID/rev/section] | [S: ___; B: ___; DC interface differences] |
| DC and mechanicalDC-02 | [M/P; current at buyer voltage for startup, idle, active RF, dual-active if relevant; DC Test IDs] | [Current by supply voltage and operating state] | [Power-state test-plan or record ID/rev; Test IDs] | [S: ___; B: ___; current differences] |
| ThermalTHM-01 | [M/P; ambient range, cooling, heat transfer, RF duty and duration; THM Test IDs] | [Thermal conditions and limits by state] | [Thermal specification/test-plan ID/rev; Test IDs] | [S: ___; B: ___; thermal differences] |
| MechanicalMEC-01 | [M/P; dimensions, mass, mounting holes, connector orientation, clearance] | [Revision-matched outline and interfaces] | [Mechanical drawing ID/rev; mounting detail] | [S: ___; B: ___; fit differences] |
| Quantity and quotationQUO-01 | [M/P; sample/production quantities and price-break points] | [Unit price/currency by quantity; MOQ] | [Quotation ID/rev/line] | [S: ___; B: ___; price/MOQ differences] |
| Quantity and quotationQUO-02 | [M/P; required lead time and shipment milestones] | [Quoted lead time and shipment schedule] | [Quotation/schedule ID/rev] | [S: ___; B: ___; schedule differences] |
| Quantity and quotationQUO-03 | [M/P; delivery location and commercial delivery terms] | [Quoted delivery place and terms] | [Quotation/terms ID/rev] | [S: ___; B: ___; delivery differences] |
| Quantity and quotationQUO-04 | [M/P; quotation validity through required date] | [Quote expiration date] | [Quotation ID/rev/date] | [S: ___; B: ___; validity differences] |
| Quantity and quotationQUO-05 | [M/P; warranty term and required coverage] | [Offered term and coverage] | [Warranty terms ID/rev] | [S: ___; B: ___; warranty differences] |
| Quantity and quotationQUO-06 | [M/P; included cables, accessories, software, documents, HW/FW baseline] | [Included/excluded items and revisions] | [Scope-of-supply ID/rev; package manifest] | [S: ___; B: ___; missing deliverables] |
| Acceptance and traceabilityACC-01 | [M/P; test-plan revision, Requirement/Test ID map, pass limits and uncertainty rule] | [Proposed test coverage, limits and deviations] | [Acceptance-plan ID/rev; Test IDs] | [S: ___; B: ___; missing tests/limits] |
| Acceptance and traceabilityACC-02 | [M/P; per-unit, sampled or representative scope; report fields and format] | [Evidence coverage, milestone and report format] | [Report-template ID/rev; sampling plan] | [S: ___; B: ___; evidence-scope differences] |
| Acceptance and traceabilityACC-03 | [M/P; unit ID/S/N-to-report link at delivery; TRC check IDs] | [Identification scheme and traceability plan] | [Traceability procedure ID/rev; check IDs] | [S: ___; B: ___; traceability gaps] |
Swipe horizontally to complete all RFQ response fields →
Technical quote approval requires a buyer decision on each mandatory requirement, a documented disposition for every D or O entry, and named evidence deliverables for post-award testing.
Send the completed RFQ to the RF SKYPOWER engineering team for an F1/A01 specification review. Include the intended use and region, frequency and waveform plan, required RF-port count, per-port bandwidth and power limits, any PA input boundary, control files, DC/thermal/mechanical limits, quantity, and test-report scope. We can review the offered configuration, its interface documents, and the evidence needed for the project.