Custom IQ signal generator test setup with an SDR signal-source module, laptop, DC power supply, inline RF attenuator, and spectrum analyzer for conducted replay validation.

A custom IQ signal generator can display a file in its waveform list while the RF replay uses the wrong sample rate, gain, or output selection. Acceptance ties the exact exported IQ file and device state to conducted measurements at a named SMA port, using limits agreed before testing.

Build that trace from the first test run. Otherwise, even a clean spectrum capture may be difficult to associate with the waveform that was delivered.

1. What Must a Custom IQ Replay Validation Prove?

Four-stage IQ replay validation process linking file verification, waveform selection, observed SMA RF output, and comparison against approved limits.

Keep four states separate in the acceptance record:

  • File verified: The exported bytes decode as the approved sample type, order, length, and amplitude convention; the host file has a recorded checksum.
  • File listed and selected: The device software shows the file entry and selection state; transfer records establish how it reached the device.
  • RF observed: The designated physical RF connector produces a signal under the logged source configuration.
  • Replay accepted: Corrected measurements at that connector satisfy limits agreed for the same file, firmware, playback mode, and test conditions.

Compare a stored-file checksum or readback against the exported file when the firmware supports it. Otherwise, keep the host checksum, controlled transfer log, selection record, and the procedure used to associate the selected entry with the RF capture. Label this as transfer-and-selection evidence, rather than a device-side byte comparison.

The SDR converts IQ samples into an RF waveform under its carrier, playback-rate, and gain settings. Log those settings alongside the file identity.

The reviewer should be able to follow one chain: file hash → transfer and selection evidence → source settings → measured SMA output → limit and disposition. Record measurements without agreed limits as observations; assign Pass only against an approved criterion.

2. What Must Be Defined in an IQ File Before Loading?

Interleaved I and Q samples arranged as 16-bit components, showing four bytes per complex IQ pair and the corresponding file payload calculation.

Agree on the byte-level interface before transferring the file. The HZS1006000-F1 manual describes signed 16-bit interleaved IQ, arranged as I1, Q1, I2, Q2, ...; confirm byte order and the importer’s exact rules for the installed firmware. Count complex I/Q pairs, not individual 16-bit numbers.

For a headerless, unpadded file containing N such pairs, the expected payload size is 4 × N bytes: two components times two bytes each. A size mismatch can expose truncation, unexpected header bytes, or an incorrect sample-count convention before the file reaches the SDR. Files with headers or padding require the corresponding documented byte accounting.

Use the IQ File and Replay Configuration Record to define the export and intended source state for each file and firmware revision.

File definition, values to record, and verification evidence for custom IQ replay
FieldValue to recordVerification evidence
File nameExact name, extension, and any fixed naming tagDirectory listing and software selection
File versionRevision or release identifierApproved file manifest
File checksumExported-file hash and algorithm, such as SHA-256Host verification; stored-file comparison if supported
Data type and bit depthActual encoding and bit depthExport specification and decoded sample inspection
SignednessSigned int16 as documented for F1; confirm negative-value encoding for the intended firmwareKnown-pattern decoded values
Byte orderLittle-endian or big-endianByte-level decode check
I/Q orderI/Q interleaving, component sign convention, and expected spectral orientationKnown-pattern decode check
Complex sample count, NNumber of I/Q pairs, excluding header and paddingParser count
Payload size and framingPayload bytes; any header or padding bytesByte count against 4N for raw int16 IQ
IQ sample rate, f_sDesigned complex samples per secondExport manifest and verified device consumption rate
Digital amplitude conventionNormalization, conversion scale, rounding and clipping ruleExport settings and sample statistics
Target RF frequency and bandwidthIntended carrier and signal bandwidthApproved replay requirement
Playback modeSingle run, repeat, or other verified modeDevice/firmware configuration record
Target device and firmwareModel, unit identifier, firmware and host-software revisionDevice identification and version log
File verification statusPending, File Verified, or Requires RevisionDecoder check, reviewer, and evidence ID

Swipe horizontally to review the complete file definition →

The F1 instructions use name_0m.sc16 and identify _0m as a fixed naming element, while other examples show .cs16 and .c16. Confirm the accepted extension and parsing rule for the installed firmware before locking the export script.

3. How Should IQ Amplitude Scaling Be Validated?

Common amplitude scaling applied to I and Q samples with rounding and clipping before signed 16-bit conversion, using an illustrative 80% full-scale target.

Determine the digital amplitude before adjusting any RF gain control. When exporting floating-point I/Q to a signed integer stream, use one documented multiplier for both I and Q, then apply the specified rounding and clipping policy. Separate normalization of I and Q changes their relative amplitude and can distort the intended waveform.

Signed 16-bit values occupy −32768 through 32767. In an illustrative offline conversion, suppose the largest absolute I or Q component is 0.95. Mapping that component to 80% of the positive 16-bit limit gives a common multiplier of approximately 0.8 × 32767 / 0.95 and a maximum component near 26,214 counts. This 80% target is an example file-conversion rule; set the actual headroom from the waveform contract.

Decode the exported bytes. Compare component maxima, complex-envelope peak, RMS magnitude, crest factor, and clipped-sample count against the approved source data. Define conversion-error limits for the waveform and, if clipping is intentional, document the expected spectral effect. These are digital file checks; analog output level is measured separately.

Keep three numbers distinct: file scale, SDR gain setting, and power measured at the SMA connector. Establish the output level in dBm through a conducted measurement under the selected waveform and source settings.

4. How Do Sample Rate, File Length, and Looping Affect Replay?

IQ sample amplitude waveform showing a 0.1-second loop boundary for one million complex samples replayed at 10 MS/s.

For N complex I/Q pairs consumed at f_s pairs per second, the nominal one-pass duration is T_file = N / f_s. One million pairs played at an effective rate of 10 MS/s last 0.1 seconds, assuming no resampling.

A different consumption rate changes both duration and baseband frequency offsets. For F1, establish how the installed firmware maps file rate to playback rate; the software bandwidth setting alone does not define f_s. A known timing or frequency marker at the RF output can verify the effective rate. Record the export rate and the measured or documented replay rate separately.

For a periodic file, check whether the transition from the last stored sample to the first follows the expected sample-to-sample amplitude and phase evolution; the endpoint values need not match. Inspect a timed RF capture across the actual loop boundary for gaps, transients, or unexpected spectral components.

Keep file duration separate from command-to-output latency, startup settling, trigger response, and gaps between repetitions. Specify whether the project requires a single play, continuous repeat, timed restart, or an externally controlled start. The availability and accuracy of each mode must be confirmed for the actual firmware and measured against the project’s timing reference.

5. How Is a Custom IQ File Loaded into the Intended SDR Output?

HZS1006000-F1 signal source showing USB IQ file transfer, bidirectional RS422 host control, file update sequence, and a single SMA RF output.

The HZS1006000-F1 instructions describe the custom-file transfer sequence: connect the F1 to a computer by USB data cable until its storage appears as a removable drive, copy the waveform, and safely eject the drive. Reopen the control software, use Update File, restart the module as instructed, and select the waveform from the refreshed list. USB transfers the file; RS422 is used for host control.

For each F1 run, associate the host file checksum and USB-transfer record with the Update File operation, software selection, and subsequent RF capture. Log firmware, center frequency, bandwidth setting, gain, playback mode, PHY selection, and the connected SMA port. F1 uses Dual-PHY internally and has one external SMA RF output.

The HZSDR1006000-A01 in the RF SKYPOWER SDR signal-source module range has two independent physical SMA RF outputs, as documented in its product manual. Its available instructions do not verify customer IQ-file import. Before applying this replay procedure to A01, obtain firmware-specific support for the file format, transfer method, and channel playback. If supported, identify RF OUT 1 or RF OUT 2 on each separate capture and acceptance record.

6. Which Measurements Verify the Actual RF Replay?

HZS1006000-F1 SDR signal source connected to a DC supply and spectrum analyzer through a rated attenuator, with the SMA RF output defined as the measurement reference plane.

Begin with an expected RF signature derived from the approved IQ file and replay settings. For a file with an intentionally asymmetric spectrum or a known baseband frequency-offset marker, record the expected RF sideband and offset under the chosen I/Q convention. A measured mirror image or incorrect offset can reveal an I/Q sign, ordering, or playback-rate error that a total-power reading would miss.

Measure through a controlled, low-power 50 Ω conducted path: actual SDR RF SMA output → appropriately rated attenuation and cable → spectrum or vector signal analyzer. Protect the instrument input before enabling the source. Name the SMA connector as the reference plane, and log the path-loss characterization and instrument settings.

For a properly characterized passive path, the SMA-plane level in dBm is the analyzer input reading plus intervening loss in dB. Apply that correction once, accounting for any compensation already enabled in the instrument, and retain raw and corrected data. For wideband spectra or integrated-power measurements, apply frequency-dependent corrections where path loss varies materially across the band; otherwise document the path’s flatness and uncertainty.

Compare the actual RF replay with pre-agreed limits for the waveform:

  • Frequency placement and signature: Check the RF center, known offset markers, sideband direction, and any intended time-varying spectral features.
  • Occupied spectrum: Compare bandwidth and spectral shape using a specified integration method, span, RBW, detector setting, and mask where relevant.
  • RF level and peaks: Measure average channel power over a defined integration bandwidth and a separate RF peak metric, such as time-domain peak envelope power. Specify the acquisition bandwidth, method, and observation window. The highest point on a spectrum trace is not the waveform’s peak envelope power.
  • Unwanted energy: Evaluate relevant images, spurs, and out-of-band components with an adequate noise floor and declared bandwidth.
  • Modulation metrics, if applicable: Use EVM only with a known valid reference and documented demodulation settings.

Save the instrument ID and calibration status, raw trace or capture, analyzer setup, path correction, file hash, firmware, and playback state under one evidence ID.

These measurements characterize the signal-source SMA output. If the source will feed an amplifier, the conducted checks before PA integration must use the PA input reference plane and account for the connecting RF path.

7. How Should Replay Repeatability Be Tested?

IQ replay repeatability workflow comparing baseline measurements with start-stop, file reload, and restart trials under fixed test settings.

To test repeatability, replay the same identified file after defined operating events. Establish a baseline with the file hash, unit serial number, firmware, output port, carrier, bandwidth, gain, playback mode, supply state, temperature, test-path correction, and analyzer setup fixed.

Set the trial count and settling interval, then capture repeated starts and stops, a controlled reload, and a power cycle or restart with settings restored. Compare each run with the baseline: record, for example, ΔP_i = P_i − P_reference for corrected average RF power, the largest frequency-offset deviation, and the spread in occupied bandwidth. When both power readings are in dBm, ΔP_i is in dB. Apply the project-approved variation limits to each comparison.

If a difference exceeds a limit, first compare the recorded settings, file identity, cables, loss corrections, and instrument state. A different IQ checksum, firmware revision, PHY or RF channel, gain, or supply setting defines a new condition; a previous result is applicable only with documented equivalence or new measurements.

For cold, hot, or long-duration trials, record stabilized temperature, dwell or observation time, and RF measurements taken after the condition is reached. Assess replay accuracy and timing at those test points rather than inferring them from the module’s published operating-temperature range.

8. What Should a Custom IQ Replay Acceptance Record Include?

Blank custom IQ replay acceptance record showing file identification, device details, test conditions, measurement criteria, evidence fields, and Not Tested statuses.

A reviewer should be able to interpret the result without asking the tester what a screenshot means. Give each run an ID linked to the file checksum and revision, module serial number, firmware, date, instrument and calibration IDs, playback settings, correction file, and the acceptance specification revision.

The Custom IQ Replay Acceptance Matrix — Blank Template (No Measured Results) separates the test method, measured result, raw and corrected readings, repeat conditions, and evidence IDs. An em dash marks a field awaiting test data; Not Tested is the starting status. Set conditions and limits before the test, then attach the original data under each evidence ID.

Blank acceptance template for custom IQ file decoding, RF replay, spectrum, power, and repeatability evidence
Acceptance itemFile / device IDDefined conditionLimit / sourceRF reference planeMethod / instrument setupMeasured resultRaw / corrected readingRepeat conditionEvidence file IDStatus
File decoding and selectionFile hash + model/S/N/firmwareEncoding, byte count, exact file selectionApproved file contract and importer ruleN/A — digitalParser version, host hash, software selection log—— / N/ARe-decode frozen hash; document each transfer and selection—Not Tested
Digital scale and clippingSame file and unitCommon I/Q scale, rounding and clipping ruleApproved digital envelope and error limitsN/A — digitalOffline parser and source-file comparison—— / N/ARe-decode same file and parser revision—Not Tested
Duration and loop boundarySame file and unitN, verified f_s, playback and loop modeProject duration and seam limitsNamed SDR SMA outputTimed RF or VSA capture; clock reference—— / —Agreed starts and loop captures with settling noted—Not Tested
RF frequency and IQ signatureSame file and unitCarrier, known IQ offset, gainExpected marker and frequency toleranceNamed SDR SMA outputSpan, RBW, detector and frequency reference—— / —Identical settings across the specified captures—Not Tested
Occupied spectrum and spursSame file and unitWaveform, carrier and configured bandwidthApproved OBW, mask and spur limitsNamed SDR SMA outputOBW rule, span, RBW, noise floor and loss correction—— / —Agreed repeat captures at matched settings—Not Tested
Average channel power and defined RF peakSame file and unitGain, 50 Ω load, supply, waveformAverage-power and peak limitsNamed SDR SMA outputChannel integration BW; peak metric and time-capture BW/window; attenuation—— / —Power captures across the agreed trial and settling conditions—Not Tested
Reload and restart repeatabilitySame file and unitTrial count, reload, restart, settling and temperatureApproved run-to-run variation limitsNamed SDR SMA outputMatched RF/VSA setup, correction file and comparison method—— / —Specified start, reload and restart sequence—Not Tested

Swipe horizontally to complete the full IQ replay acceptance record →

Use Pass when file identity is traceable and corrected measurements meet every applicable limit over the required trials. Use Review for missing limits or unresolved evidence, Fail for a measured violation, and Not Tested for an unperformed check. Keep development captures separate from the serial-number-specific acceptance records used for delivery.

Conclusion

Replay acceptance is a scoped result: an approved IQ file, its transfer record, and corrected RF measurements meet predefined limits for one device, firmware, output port, and set of test conditions. The record also states which reload, restart, and environmental trials were completed. Calibrated output across other gain settings, temperature-dependent timing, and downstream PA behavior require their own measurements.

To run the test, freeze the file manifest, verify its byte count and scaling, confirm the firmware’s import and playback-rate rules, then collect conducted RF captures and restart comparisons against approved limits.

For an RF SKYPOWER engineering compatibility review or RFQ, send the proposed model and firmware plus the IQ file manifest: encoding, byte and I/Q order, size, checksum, sample rate, scaling, and crest-factor requirements. Include carrier frequency, bandwidth, replay and repeatability mode, target RF level and reference plane, supply and thermal conditions, and the required acceptance limits and evidence. For A01, request confirmation of customer IQ-file import and the intended independent RF output before treating it as a custom-replay option.